Accurate electronic gravimetric scale with hanging probe assemblies
Adjustable precision lift stage with steady wheel
Suspended probe system in PURE Platinum for optimal precision (no Pt-Ir alloy)
Glass vessel for liquid sample
Display of surface tension value expressed in mN/m (dyne/cm) measured with the Wilhelmy method
and of the surface tension and the interfacial tension (mg) by means of an external software.
Platinum du Nouy ring made to the ASTM D971 specifications
Optional automatic jack with programmable speed
Optional DYNTENSION Windows softwares for dynamic measurements
Optional Glass plates with micro roughened surface (dimensions 24x24x0.15 mm)
Optional Platinum plate
Optional thermometric probe Pt 100 1/3 DIN
Optional floater calibrated in weight and in volume and double wall cylinder for relative density measurement of oils and water (this is required to calculate and correct the surface and the interfacial tension forces
Optional thermostatic vessel for temperature control of the sample during the test process
Optional special pan and certified masses for external metrological control
1.2 Technical specifications
Measurement principle: Torsion wire
Precision: +/- 0.1 mN/m (dyne/cm) with du Nouy Ring and +/- 0,2 mN/m with Whilhelmy plate
Precision in Contact Angle +/-0,5�
Dimensions: L220 x D355 x H350 mm
Capacity: 1-60000 mg/mm or 0.1-550 mN/m /Dyne/cm) or optional 0-180� Contact Angle
Max. sample diameter 120 mm
Stage travel 150 mm +/- 0.01 mm
Temperature measurement range: 7 to 34�C
Temperature accuracy: 0.025�C
Temperature reproductibility: +/- 0.05 �C
Temperature readability: 0.1�C
Density measurement range: 0.5 to 2.25 g/ml
Density readability: 0.00005 g/ml
Density precision and reproductibility: +/- 0.00005 g/ml
Electronic zeroing before measurement
Autocalibration with internal mass
1.3 Technical details of some optional supplies
Automatic jack with programmable speed (from 21 to 328 mm/s or from 0,004 to 21 mm/s)
DYNTENSION Softwares with the following performances:
1. Real-time display on PC of:
force changes (in dyne) during the measurements
testing time
surface tension values (and interfacial tension on request)
2. data recording (useful for other experiments)
3. changing value of plate perimeter (if different from standard)
4. selection of manual or automatic system for determination of end of measurement
5. Advantages:
The measure is independent of the operator subjectivity and the instrument control is complete, with method storage, development, dynamic hysteresis curve, real time buoyancy correction, Administrator mode to protect standard methods from unauthorized modification, GLP to flag any changes to the original data, fully automatic calibration and a complete range of analyses with guide step by step for development of new methods
Possibility to change the position of the elevator for 0 to 150 mm and the speed too
Control of the change in speed allow a better precision in the measurement
The software stores the data of each test (speed, positions, tensions�)
Display of the necessary time for execution of the test due to programmed movements and speed
Thermometric probe Pt 100 1/3 DIN:
1. range of measure: 7-34�C
2. accuracy: 0.025�C
3. reproductibility: � 0.05 �C
4. readability: 0.1�C
Glass plates with micro roughened surface (dimensions 24x24x0.15 mm)
Platinum Wilhelmy plate
Platinum du Nouy ring
Special floater calibrated in weight and in volume with holder and double wall cylinder for relative density measurement, made of pure Platinum, borosilicate glass and standard solid of Silicon:
1. range of measure for the density: 0.5 � 2.25 g/cm3
2. readability: 0.00005 g/cm3
3. precision and reproductibility: � 0.00005 g/cm3
Other probe types (Lenard frame, rods, discs, tubes, cones and spheres)
Specific container for sample thermostatation
Special pan and certified masses for metrologic control